Click to zoom
Electronic Torque Tester And Calibrator
The TTC2800 has the same features as the TTC2000 series except for the following enhanced features:
• Electric motor powered crank for easy calibration
• Is offered in 110 V version (TTC2800/Complete TTC2800SYS or 220 V version (TTC2822/Complete system TTC2822SYS)
TTC2000SYS Complete Master Torque Calibration System (Manual) includes: TTC610 Digital Monitor, TTC600 2000 ft-lb Mechanical Loader, SM0773PU Tool Cabinet w/ Casters, TTC400 4-in-1 Transducer, TTC5000-1 Bracket, TTC12 3/4" 600 ft-lb Transducer, TTC14 1" 2000 ft-lb Transducer, TTC5500-1 Extension Arm, 2000-SW WedgeLink Software, TTC503 Download Cable.
TTC2800SYS Complete Master Torque Calibration System (Motorized) includes: TTC2800 Monitor, Loader and Tool Cabinet w/ Casters, TTC400 4-in-1 Transducer, TTC5000-1 Bracket, TTC12 3/4" 600 ft-lb Transducer, TTC14 1" 2,000 ft-lb Transducers, TTC5500-1 Extension Arm, 2000-SW WedgeLink Software, TTC503 Download Cable
Features
• Accuracy: ±0.25% of indicated value, CW and CCW, from 10–100% of full scale
• Units of Torque: ft-lb, in-lb, in-oz, N•m, dN•m, Kgm, Kg-cm
• Units of Force: lbf, ozf, n, dN, kp, gg
• Four Modes: TRACK, PEAK HOLD, FIRST PEAK, POWER TOOL
• Includes built-in low profile serial printer
• Transducers available from 5 in-oz to 2,000 ft-lb
• Loader hand crank maximum input torque is 8 ft-lbs, maximum output is 2,000 ft-lb
• All transducers are individually serialized with certificates of calibration traceable to N.I.S.T.
• Programmable automatic or manual options for CLEAR, STORE or SEND
• RS232 serial port for downloading data to PC
• Operating Temperature: 10–32 °C (50–90 °F)
• Automatic lockup in the event of transducer overload
• Data storage/recall (with date/time stamp) up to 3,000 readings
• Dual Voltage: 110 V or 220 V• Real Time Clock
• Smart “Plug and Play” transducers
TTC2800SYS | |
Description | Electronic Motorized Torque Tester/Calibrator |
Capacity | 8 digits ±32,000 counts (16 bit A/D) |
Accuracy* | ±0.25% of reading at 25 °C (with TTC Transducer calibration) |
Temperature Drift | +0.03% / °C (+0.017% / °F) |
Maximum Range Display | 2-line x 16 character 5 x 8 dot-matrix LCD used for MAX. Transducer range, Units, Angle, Calibration, Date/Time, Statistics, Torque/Force or Torque/Angle Limits Set, Data Store/ Recall, Printer Set Up |
Modes | Track, Peak Hold, First Peak, Power Tool |
Operating Temperature | 10-32 °C (50-90 °F) |
Storage Temperature | -20-50 °C (-2-122 °F) |
Humidity | Up to 90% non-condensing |
Power Supply | 120 VAC ±10%, 50/60 Hz @3.14 A (including motor current). (Includes stepdown transformer for 240 VAC operation.) |
Data Storage/ Recall | 3,000 Measurements |
Statistical Analysis | Max, Min, Range, Mean, SigmaN, Sigma, Cp, Cpk, % Error,-NoGo, +NoGo |
Histogram | Lower Set Limit, Upper Set Limit, 10 Divisions |
Printer/Computer Serial Output Port | RS232 (True), 300-19.2K Baud |
Computer Serial Com Port | RS232 (True), 300-19.2K Baud (Optional) |
Analog Output | +(CW/-(CW) 1.8 V at Transducer Full Range Linearity, ±1% of reading |
Loader Control Relays | Two, Normally Open, Form A, Rated 12 DVC @ 1/2 A close contact at 110% CW or CCW or torque/force transducer range |
Loader Hand Crank | Input torque 8 ft-lb Maximum, Output Torque 2,000 ft-lb Maximum |
Motorized Loader Modes | Manual; Auto Dial; Auto Click |
Motorized Loader Power Supply | 20 V AC ± 10% Hz @ 3.14 A (including motor current); (optional step-down transformer for 240 V AC operation) |